Security Systems
Grasbrunn
05-February-2015
Page 6 of 38
Operator Client can crash when camera sequences are running and the
computer is locked, for example by pressing “Windows-key + L”. Please
avoid locking the computer when running sequences.
CameoSDK, Client scripts
Most client scripts are not supported when Operator Client is connected to a Management Server
with a previous version.When a user with restricted rights to access all cameras, executes a
client script (via Logical Tree) that calls CameraManager.GetCameraInfoList(), ALL cameras are
returned, not only those, the user has access rights for.
Management Server
When a configuration from a previous Bosch VMS version is imported, new events that did not
exist in the previous version, do not appear. To get the new events, you must manually activate
the configuration and restart the Central Server service.
If you use a Management Server with multiple network adapters, it can happen that the time
synchronization of encoders and decoders does not work correctly. To avoid issues ensure that
the IP address of the time synchronization server is configured in the Management Server
configuration file (TimeServerIPAddress in the app-config file CentralServer.exe.config).
If the IP address of a Management Server computer is changed during the MVS is offline, this
new IP address is not transferred when the MVS becomes online again. Please perform a
configuration change and activate. For example you can change the Day schedule.
MVS/Web-Client
You cannot add an MVS in Configuration Client when the time between the Configuration Client
computer and the MVS computer is not synchronized. Please ensure that the time is
synchronized between the affected computers.
Following action in Web Client are not logged:
- Toggle relays, PTZ control, search for metadata; export video
Following user actions are logged:
- Log on and log off.
Restrictions of feature permissions for selected cameras do not work for Web Client and Mobile
App. Only the restriction for the access is working correctly.
Restart the IIS after changing the Management Server for MVS is needed.
Devices
The first firmware update of a VIP XD HD reports a false error. The update is nevertheless
successful. The next update is executed without error message.
VIDEOJET Decoder 7000 supports ONVIF via VSG, VIDEOJET 3000 does not.
You can add a DVR device without using the DIVAR Admin account.
The following requirements must be met to configure ROI on the Cameras & Recording table:
- Codes for stream 2 must be a ROI codec.
- Stream 2 must be used for Live.
- No recording configured for stream 2.
On PTZ and ROI camera Image panes, the MD icon is not visible when video content analysis is
enabled. The feature is working as expected.